Plexus MA300 Methacrylate Adhesive
At a glance
- High strength + impact resistance
- For bonding metals and plastics
- Fast curing
Product description
Plexus MA300 is a 2-component acrylic adhesive designed for structural bonding of thermoplastic, metal and composite assemblies. MA300 offers a combination of high strength and stiffness as well as the ability to bond a wide range of materials. Plexus MA300 is supplied in ready to use cartridges. Suitable mixing nozzles and an application gun are required to use this adhesive.
Applications
Plexys MA300 is suitable for bonding the following applications:
- ABS
- Acrylics
- FRP
- Gelcoats
- Steel, Carbon
- PVC
- Polystyreen
- Polyesters (including DCPD modified)
- Vinyl Esters
- Styrenics
- Urethanes (general)
- Aluminum
- Stainless steel
Specifications
Colour: cream
Specific weight: 0.97 g/cm3
Shear strength: 20-26 N/mm2
Viscosity: 40.000 - 70.000 mPa.s.
Gap filling: to 4 mm
Operating temperature: -55°C to +121°C
Working time: 4-6 minutes
Fixture time: 12-15 minutes at 23°C
Packaging:
- 50 ml double cartridge (application gun and mixing nozzles required)
- 400 ml double cartridge (application gun and mixing nozzles needed)
Application:
Mixing nozzles:
- Mixing nozzles A (50 ml)
- Mixing nozzles D (400 ml)
In combination with the right application gun and mixing nozzles, Plexus MA300 is ready for immediate use!
Product properties
The key technical properties clearly listed in one place.
- Article number
- LIJ000519
- Colour
- Lichtgeel
-
Open time is the period during which an applied adhesive, sealant or mortar can still be assembled, positioned or adjusted. It is usually given in minutes under specified conditions, often around 20 or 23 °C. Open time generally starts at application and may differ from the working time after mixing.
- 1 tot 10 minuten
-
Gap-filling capability describes how wide a gap or joint an adhesive or sealant can bridge, usually in millimetres (mm). The stated maximum is not necessarily the recommended adhesive layer thickness: a narrower joint may be needed to achieve good bond strength.
- Up to 4 mm
-
Adhesive type describes the family of adhesive or sealant, such as epoxy adhesive, (methyl)methacrylate adhesive, polyurethane adhesive or polymer sealant. Its chemistry affects processing, curing, flexibility and adhesion. Products of the same type may still differ, so check the suitable substrates and application instructions.
- Methyl Methacrylaatlijm
-
This property lists the substrates on which an adhesive, resin or coating can achieve strong adhesion according to the product information. The result also depends on surface preparation.
- Cleaning and degreasing: removes dirt, oil and other substances that interfere with bonding.
- Sanding or roughening: can improve adhesion when suitable for the substrate.
- Primer: required or recommended for some surfaces.
Materials such as PE, PP and PTFE are difficult to bond with many conventional adhesives and may need a specialist adhesive or pretreatment. If in doubt, test adhesion on a small area.
- ABS, Plexiglas (PMMA), Polyester (FRP), Staal, Roestvast staal (RVS), PVC, Polystyreen, Polyurethaanschuim (PUR/PIR), Aluminium
-
Initial strength is the strength an adhesive joint develops shortly after the parts are joined. For some adhesives, the specification gives the time needed to reach a certain strength, for example 20 minutes to reach 1 N/mm² on aluminium at 23 °C. N/mm² (newtons per square millimetre) measures stress and is equivalent to MPa. The joint may not have reached its final strength at that point.
- 12-15 minutes (at 23 °C)
-
Shear strength indicates how much stress a bonded joint can withstand when forces try to slide the joined parts parallel to the bond line. It is usually expressed in MPa (megapascals) or N/mm² (newtons per square millimetre): 1 MPa = 1 N/mm². A value of 20 MPa therefore represents a test stress of 20 N/mm². Substrate, overlap, adhesive thickness and test conditions affect the measured strength.
- 20-26 MPa
-
Density describes the mass of a material per unit volume. Values may be given in g/cm³, kg/L or kg/m³; 1 g/cm³ equals 1 kg/L. For example, one litre of a liquid with a density of 1.2 kg/L weighs approximately 1.2 kg. Density helps convert between weight and volume, but it can vary with temperature.
- 0.97 kg/L
- Net contents
- 50 ml
-
Working time is the period during which a product remains workable after mixing or activation, usually given in minutes at a specified temperature, often 20 °C. With reactive resins, the chemical reaction also continues in the mixing container, and larger quantities or higher temperatures can shorten this time. Working time is different from gel time and full curing time.
- Approximately 4-6 minutes
-
Viscosity measures how easily a liquid flows, or how thick it is. Dynamic viscosity is usually expressed in mPa·s (millipascal-seconds), sometimes in cP (centipoise); 1 mPa·s = 1 cP. A lower value usually means a more free-flowing liquid, while a higher value indicates a thicker product. Temperature and test method strongly affect the value. Note that mPa·s is different from MPa, which is used to express mechanical strength.
- 40.000-70.000 mPa·s
-
Heat resistance describes the temperature a material can withstand after correct processing and curing, usually expressed in degrees Celsius (°C). Continuous exposure is different from a brief temperature peak, and mechanical loading may also affect the limit. Heat resistance is not the same as the temperature at which the product can be applied.
- -55 to 121 °C
Safety information
Read the warnings and use appropriate protective equipment before handling the product.